STANDARD CONSTRUCTION
TECHNIQUE
- Silver thread ( up to 400ºC ) and nichrom
thread (up to 600ºC.) from thermoelement to head.
- Isolation by ceramic bead.
- Outer protective case in AISI 316 material.
- To avoid breaking the element and ceramics during
transport, it is filled with perfectly compacted magnesium oxide
powder.
It is put under a procedure developed at
EPCO that guarantees an isolation greater than 20 Mega Ohms at
250 V. A 20 º C.
Platinum sensors according to DIN
43760, with tolerances 1 DIN and 1/3 DIN, (we also equip thermoelements
with nickel sensors)
Head. standard in aluminium alloy,
with ceramic floating socle, antivibrations.
It's possible to make the
probes with an alternative method of construction, using continuos
jacketed conductor and magnesium oxide mineral isolation.
|